Firmware PowerBOX 4Kx: 3.2.6 (3,4 MB)
2022/11/02
= Firmware for NETIO PowerBOX 4Kx – version 3.2.6-1.53 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSES OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This firmware is for device:
- PowerBOX 4KF
- PowerBOX 4KE
- PowerBOX 4KG
==== Main system v 3.2.6 ====
- Scheduler - fix of late afternoon / night interval incorrect saving
- Scheduler - possibility to select again "None" after selecting other before
==== Low level system v 1.53 ====
- Bug fixes and system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSES OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This firmware is for device:
- PowerBOX 4KF
- PowerBOX 4KE
- PowerBOX 4KG
==== Main system v 3.2.6 ====
- Scheduler - fix of late afternoon / night interval incorrect saving
- Scheduler - possibility to select again "None" after selecting other before
==== Low level system v 1.53 ====
- Bug fixes and system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerBOX 4Kx: 3.2.5 (3,4 MB)
2022/05/12
= Firmware for NETIO PowerBOX 4Kx – version 3.2.5-1.49 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSES OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerBOX 4Kx
==== Main system v 3.2.5 ====
- Activation of static IP mode by button
- Modbus/TCP protocol update for devices with energy metering and digital inputs
- Telnet protocol - commands response format
- MQTT-flex protocol - parameters length update, MS Azure IoT Hub compatibility
- Default PAB, Rules configurations update
- Bug fixes and the system optimalization
==== Low level system v 1.49 ====
- Bug fixes and system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerBOX 4Kx: 3.2.0 (3,3 MB)
2021/11/17
= Firmware for NETIO PowerBOX_4Kx – version 3.2.0-1.48 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerBOX_4Kx
==== Main system v 3.2.0 ====
- PAB: (Power Analyzing Block) defines sets of conditions for creating events from the time course of measured variables (current, voltage, S0 pulses etc.). You can then work with events in Rules.
- Watchdog: Watchdog is a tool that allows you to ping a given (IP) address and evaluation of success.
- Rules: Rules allow to trigger follow-up actions based on events from PAB, Watchdog or Digital Inputs (DI). The actions can change output states (turn OFF, turn ON, toggle, etc.) or trigger an alarm in NETIO Cloud.
- Support for NETIO Cloud Premium
- Support for remote FW update from NETIO Cloud
- Support for control by mobile app NETIO Mobile2 over NETIO Cloud
- Bug fixes and the system optimalization
==== Low level system v 1.48 ====
- Bug fixes and system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerBOX_4Kx
==== Main system v 3.2.0 ====
- PAB: (Power Analyzing Block) defines sets of conditions for creating events from the time course of measured variables (current, voltage, S0 pulses etc.). You can then work with events in Rules.
- Watchdog: Watchdog is a tool that allows you to ping a given (IP) address and evaluation of success.
- Rules: Rules allow to trigger follow-up actions based on events from PAB, Watchdog or Digital Inputs (DI). The actions can change output states (turn OFF, turn ON, toggle, etc.) or trigger an alarm in NETIO Cloud.
- Support for NETIO Cloud Premium
- Support for remote FW update from NETIO Cloud
- Support for control by mobile app NETIO Mobile2 over NETIO Cloud
- Bug fixes and the system optimalization
==== Low level system v 1.48 ====
- Bug fixes and system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
Firmware PowerBOX 4Kx: 3.1.3 (3,4 MB)
2021/05/11
= Firmware for NETIO PowerBOX 4Kx – version 3.1.3-1.43 – release notes =
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerBOX 4Kx
==== Main system v 3.1.3 ====
- SNMP: support of SNMP v3
- Option to run SNMP in parallel to other M2M API protocol
- MQTT-flex: Longer username (128 chars) a password (256 chard) support for compatibility with MS Azure
- Added Reverse Energy counters - energy delivered back to the grid from connected device
- Added non-resetable Energy counters - Energy NR, Reverse Energy NR, Total Energy NR, Total Reverse Energy NR
- Adjustment of the Phase range: 0° - 360°
- Adjustment of electrical measurement in web administration
- Improved firmware upgrade process
- SNMP bux fixes
- Bug fixes and the system optimalization
==== Low level system v 1.43 ====
- Support of the Device Power Loss Time
- Support of the Reverse Energy counters
- The system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.
* Archive contains two update packages. One for main system upgrade and the second one "mcu" marked package for main system + low level system upgrade.
XXX.package = main system upgrade package
XXX+mcu-output-restart.package = main system + low level system upgrade package --- THIS PACKAGE CAUSE OUTPUT RESTART
* When no critical infrastructure is connected to the device we recommend to use XXX+mcu.package update package.
This is for devices:
- PowerBOX 4Kx
==== Main system v 3.1.3 ====
- SNMP: support of SNMP v3
- Option to run SNMP in parallel to other M2M API protocol
- MQTT-flex: Longer username (128 chars) a password (256 chard) support for compatibility with MS Azure
- Added Reverse Energy counters - energy delivered back to the grid from connected device
- Added non-resetable Energy counters - Energy NR, Reverse Energy NR, Total Energy NR, Total Reverse Energy NR
- Adjustment of the Phase range: 0° - 360°
- Adjustment of electrical measurement in web administration
- Improved firmware upgrade process
- SNMP bux fixes
- Bug fixes and the system optimalization
==== Low level system v 1.43 ====
- Support of the Device Power Loss Time
- Support of the Reverse Energy counters
- The system optimalization
In case of any problems or questions please visit www.netio-products.com or contact the support at support@netio.eu.