The NETIO PowerDIN ZP3 is a smart power management device intended for fixed installations with DIN rail mounting, typically used in AV, IT, and industrial automation applications.

It can operate as smart switching device in a three-phase system (400 V, 3×16 A) or as smart switching device in a single-phase system with three independent channels (3x230V/ 16A).

The device is also equipped with two Digital Inputs (DI), those can be used for direct connection to a NETIO sensors, NETIO nBus (device daisy-chaining feature), or an S0 counter

Thanks to the Open API, integration with third-party systems using various protocols (JSON, Modbus/TCP, SNMP, MQTT-flex, Telnet, ...) is easy.

With the NETIO Cloud service, the outputs can be controlled from anywhere. The NETIO Cloud service, provided for a fee, uses SSL security and servers in Europe.

 

Typical applications

  • LED WALLs installation (Power OFF/ ON/ including remote RESTART)
  • Switching ON/OF/ RESTART -  3-phase systems in electrical cabinet (400V/ 3x16A)
  • Switching three ON/OF/ RESTART independent single phase outputs (3 x 230V/16A)
  • Controlling the outputs using Open API (JSON, Modbus/TCP, SNMP, MQTT-flex, Telnet, ...)
  • Integration with various third-party programs and applications.

 

 

AV drivers for integration

NETIO products can be used together with plenty 3rd party software / hardware or cloud services.

  • Atlona
  • AURORA
  • BrightSign media player (BrightAuthor]
  • Crestron (SIMPL blocks)
  • Control4
  • Cue
  • ELAN
  • Elgato Stream Deck
  • PIXILAB Blocks
  • Q-SYS
  • RTI
  • SKAARHOJ
  • Utelogy
  • and many more

>> More about  Integration partners (3rd party)

Ask for a price or technical parameters

Documents to download

   
yt_icon_white
 
Video Flyer
 
pdf_ikona_white
Flyer PDF
 
pdf_ikona_white
Manual PDF (CE)

 

Remote restarting

Switch On / Off or Restart (short Off) each output using these methods:

  • From the device website
  • From the NETIO Cloud (web service).
  • From NETIO Mobile 2 (Mobile App) over LAN or NETIO Cloud (web service)
     
  • By external mechanical switch (dry contact) connected to DI input.
     
  • Using build in Week-Scheduler function you can define several On/Off intervals per each output.
  • With build in PING WatchDog function, you can restart any LAN device when not responding to PINGs from NETIO PDU (Device frozen)
  • With build in Power consumption WatchDog function, you can restart any device powered from metered NETIO PDU output. Device frozen / sleeping / IDLE mode is detected by power consumption drop for several time.
     
  • Using AV drivers you can control Outputs from many Audio Video SW (Q-SYS, Crestron, Control4, Kramer, BrightSign, …)
     
  • There are plenty Open APIs (protocols) to control outputs / meter power consumption.
  • For example: JSON or XML over HTTP, SNMP v1 or v3, Modbus/TCP, MQTT, URL-API and others.
     
  • Using Windows executable PyNetio swtich / Toggle any NETIO output(s) from the Windows Desktop.
  • More: AN37 Outputs sequence started by Windows desktop icon (.bat file)

 

DI (Digital Input)

Every single DI is realized as 3pin terminal block. There is 12V for powering external devices like smoke or movement detectors.
There is also 4bytes pulse counter on the DI (compatible with S0 pulses). 4 bytes counter can be used for reading consumption from an external meter. You can connect there any meter with pulse output (water meter, gas meter, 3phase electricity meter, …)

PowerDIN ZP3 offers two digital inputs (DI), which can be used for direct connection to

  • NETIO T1 sensor – dedicated NETIO temperature sensor
  • NETIO TH1 sensor – dedicated NETIO temperature & humidity sensor
  • NETIO nBus – unique feature allowing daisy chaining of NETIO devices
  • Mechanical button – as dry contact to read out OPEN/ CLOSE contact
  • External electricity or water meters (pulse output).- as S0 pulse counter



>> More about DI (Digital Input)

 

External sensors

One external sensor can be connected to each DI (Digital Input). Only original NETIO sensors are supported.
-    External temperature sensor NETIO T1 (IP67 probe, 3m cable, -20℃ to +80 ℃)

Output switching based on DI state (sensor value).
With using the CR (Condition & Rules) can be local condition executed in the PDU to control one or more outputs based on DI current state or measured sensor value. Check the Condition & Rules in Glossary:.
>> More about DI (Digital Input)

 

Web_HTTPs

HTTPs

PowerDIN ZP3 device support safety communication via HTTPs by using TLS - Transport Level Security Protocol v1.2. User is able to upload customer Server Key and Server Certificate. NETIO devices support Keys/ Certificates using both cryptography methods - Elliptic-curve (ECC) & RSA.

 

 

 

AV driversAV drivers icon

We can offer you drivers (integrated device support) for these AV (Audio Video) platforms:

  • Atlona
  • Aurora Multimedia
  • Control 4
  • Cue
  • Crestron
  • Domotz
  • ELAN
  • Elgato Stream Deck
  • HSYCO
  • Kramer
  • Loxone
  • Pixilab Blocks
  • Qsys
  • RTI
  • SAVANT
  • SKAARHOJ
  • Utelogy

These integrations / drivers can be free or paid. It's individual..
Drivers not tested by NETIO products, but provided by community are listed on wiki.netio-products.com

>> More about Integration partners (3rd party)


open_api

Open API (M2M protocols)

  • SNMP v1                               AN11AN41
  • SNMP v3
  • MQTT-flex                             AN40
  • Telnet                                     AN10
  • Modbus/TCP                         AN27AN22AN37
  • JSON over HTTP                 AN21AN30AN42
  • XML over HTTP                    AN20AN31
  • URL API (http get)                AN19AN29
  • HTTP(s) Push JSON                      
  • HTTP(s) Push XML           

Regardless of the Open API used, the PowerDIN ZP3 can always be controlled from its web interface and at the same time from the NETIO Cloud service. The customer can use the NETIO Cloud service and one Open API protocol at the same time.

 

NETIO TOOLBOX

 NETIO Toolbox is set of power management industrial features integrated into all NETIO devices, design for AV integrators, IT admins, System Architects and industrial users. NETIO Toolbox trasform electrical power from a passive resources into activelly management system. It consist of core features as:
  • Manuel/ Remote/ Autonomous Restarting
  • PowerUp Sequence
  • Industrial feature as ZCS (Zero Currents Switching)
  • Time Based Power Switching (Scheduler)
  • Grouping of Device & Outputs
  • Daisy Chaining of Multiple PDUs (nBUS)
  • Thermostat Feature – Temperature Based Switching
  • Connection Error Alert

 

ZVS (Zero Voltage Switching)

An important feature of the NETIO PowerDIN ZP3 is ZVS (Zero Voltage Switching).

ZVS controls the exact time when the mechanical relay contacts close and open. The relay contacts switch the output on or off when the voltage crosses the zero level. 

  • In the long term, ZVS support reduces the product failure rate due to internal relay damage.
  • Since the relay switches when the sinusoidal voltage waveform crosses the zero level, negative effects of inrush current are significantly reduced.
  • The ZVS and PowerUp delay functions reduce the chance of circuit breakers tripping when power is restored after an outage.
  • ZVS extends the lifetime of connected equipment, especially in case of frequent on/off switching of devices that are not designed for that (such as switching power supplies).

 

>> Glossary: More about ZVS 

 

 

The switching of outlets can be time-controlled by the Scheduler with a graphical interfaceScheduler (timed switching of individual outlets)

With the Scheduler (timer) function, each output can be individually switched on or off at specified times and days of week. The switching times are easily configured in a graphical interface.
 
  • Each output can have its own schedule
  • When a schedule is active, outputs can still be controlled with NETIO Cloud, the web interface and Open API
  • Scheduler functionality can be enabled/disabled (not edited) for each output from the NETIO Mobile 2 app.
     
  • Scheduler does not need an internet connection. However, a time source is needed – provided over the internet or, for example, by a local ADSL / WiFi router.
  • For special usage the Scheduler can be combined with PAB (Power Analyze Blocks):
    • Switching time is based on current sunrise/sunset based on your location
    • Whatever happend, defined output can be switched off on defined time (midnight for example).
    • Ask for more..

 >> More information about the Scheduler

 

Condition & RulesIcon_Condition-Rules

The NETIO Conditions (PAB & WatchDog) & Rules are preprogrammed in the device. It's great tool for special usage and applications.

Customer activate these functions in script based configuration. Using Condition & Rules it is possible to define reaction of the output(s) to the switching the button (DI input) or the reaction of defined output to the (non) response of PING WatchDog. NETIO Condition & Rules are supported by all NETIO devices manufactured after 2020 with the exception of PowerPDU 4C (supports LUA scripts).

Detailed description you can find on the wiki.netio-products.com, check the "NETIO Conditions & Rules: Local device scripting" part.

 

 

User can define output state after power restoring - PowerUp statePower-Up state

 For some applications, it is important to set the power output state immediately after the device is powered on (or the power is restored after a failure). With some machines it is important to avoid momentary switch-on or switch-off. This parameter therefore defines the behavior of the power output before the standard communication with a master system starts to work.
  • On
  • Off
  • LAST state restores the last state before the power was disconnected

Delay sequence when switching outputs on (PowerUp delay)

After a power outage, some electrical equipment can be switched on with a delay to avoid overloading and tripping circuit breakers. With the PowerDIN ZP3, use these parameters: “Power-Up state” = ON / LAST, and “Output PowerUp interval” = power-up delay before switching that particular output on.

>> Glossary: PowerUp state

 

 

WatchDog Ping + Power

PowerDIN ZP3 is equipped with WatchDog PING (IP WatchDog) and WatchDog Power consumption (PAB).

  • WatchDog Ping continuously monitors whether a given process or a part of a system work as they should. If not, the WatchDog restarts the process. Can be used for all 8 outputs.
     
  • WatchDog Power is "Condition" & "Action" (PAB - Power Analysis Block & Rules) based autonomous system. It continuously monitors current (energy) of monitored device powered from any metered power output of NETIO PDU device.

>> Glossary: WatchDog PING (IP WatchDog)

>> Glossary: WatchDog - Power consumption (PAB)


 

NETIO Cloud

 The product can be connected to NETIO Cloud. Control 100 outputs from a single web screen!
NETIO Cloud is an ideal solution for remote control and restarting. It is accessible via any web browser: https://cloud.netio-products.com/
  • All devices produced by the NETIO products company can be connected to NETIO Cloud.
  • With every added device you receive free "Welcome Credit"
  • Remote PDU output control (from NETIO Mobile App or NETIO Cloud service website)
  • Multi-user feature for sharing devices in one company account
  • The User Rights (roles) can be defined for access control
  • PDU Connection Alert feature sends email notifications for PDU disconnections (connection or power failure).
  • Grouping and sub-group structure of PDUs (folders structure)
  • NETIO Mobile 2 App (Apple / Android) with user rights management
  • Open API (MQTT) to the company account of NETIO Cloud
  • The Historical Power Measurement Data can be downloaded
  • Remote firmware upgrade
  • 2 Factor Authentication
  • NETIO Cloud can be used in parallel with most of another Open API protocols.
  • Communication of PDU with the cloud service is secured (port 8883 - MQTTs - TLS).

The NETIO Cloud service is SaaS (online service). On-premise version of the cloud service is available for projects.

>> More about NETIO Cloud

 

Mobile app controlled power socketsMobile App

This device can controlled from mobile App NETIO Mobile 2 (Android & iOS).
  • LAN: NETIO Mobile 2 can control all outputs of devices within local LAN (WiFi).
  • Cloud: User account on the NETIO Cloud service can be connected to the mobile app.
 
You can do with mobile app
  • Control individual power outputs – switch ON, switch OFF, RESET
  • Read power consumption data (A, W, Wh), if this one output (device) supports energy metering

  • QR code for NETIO Mobile 2 AndroidQR code for NETIO Mobile 2 iOSActivate / deactivate the week Scheduler function per each output
  • Sorting of outputs within groups (by function or location)
  • Output grouping – default group per one device can be changed individualy
     
  • Group control - Switch the whole group of outputs On / Off
  • Group control - Activate / deactivate the week Scheduler function for each output in whole group
     
  • Change output / device name (visible in the mobile application only)
  • Add multiple devices to the mobile app.
  • LAN discover: Search your LAN/Wifi network for NETIO devices.

 

>> NETIO Mobile 2

General properties

  Phases Switched
Power
Outputs
Metered
channels
DO Relay
outputs
DI Inputs LAN WiFi Web NETIO Cloud WatchDog Scheduler Mobile App Open API
PowerDIN 4PZ 1 2 2 2 2 1 Yes Yes Yes Ping + Power  Yes iOS + Android 10 protocols
PowerDIN ZP3 3 3 0 0 2 1 Yes Yes Yes Ping + Power  Yes iOS + Android 10 protocols
PowerDIN ZK3 3 3 3 0 2 1 Yes Yes Yes Ping + Power  Yes iOS + Android 10 protocols

Technical specifications

  • LAN (RJ45): Yes
  • WiFi: Yes (2.4GHz)
  • Web: Built-in web server
  • Online demo: Coming soon
  • FW upgrade: Yes - web
  • Mobile app: Coming soon
  • Installation without a Cloud connection: Yes
  • Control button: Yes
  • Service: NETIO Cloud (for a fee)
  • M2M API protocols:
    • JSON over HTTP(s) (default)
    • MQTT-flex (extended MQTT, SSL enabled)
    • SNMP v1, v3
    • Modbus/TCP
    • XML over HTTP(s)
    • URL API (http get) (writing only)
    • Telnet (Outputs only, backwards compatible with KSHELL)

 

  • Lua scripting support: No
  • Condition & Rules: Yes
  • Scheduler function (weekly calendar): Yes
  • IP (ping) WatchDog function: Yes (Condition & Rules)
  • Power WatchDog function: Yes
  • Sending e-mails (SMTP): No
  • Power input: 3 x Terminal block (2.5mm2), 100-240VAC (50/60Hz) / max 16A
  • Power output: 3 x Terminal block (2.5mm2) – max 16A, 3x Relay + ZVS (SPST-NO) – Max 16A
  • Metered Outputs: No
  • Electrical metering: No
  • DI (Digital Inputs): 2 (dry contact) + S0 counter (4 bytes)
  • Internal consumption: Max 2 W
  • SPD – surge protection: Yes, type 3
  • ZVS (Zero Voltage Switching): Yes
  • IOC (output state independent from FW updates): Yes
  • PowerUp state of outputs: On / Off / LAST state
  • Mechanical characteristics: 108 x 91 x 62  mm = 6M (Standard DIN rail Unis - each 18mm)
  • Protection: IP20
  • Sound output: No
  • Temperature range: -20°C to +50°C
  • Relative humidity: 0 – 97 % (non condensing)

Download

Flyer: 
Flyer CS
Flyer EN
Flyer DE
Manual: 
Manual CS
Manual EN
Manual DE
Quick Installation Guide: 
Guide CS
Guide EN
Guide DE

Photo and video

Product comparison

Ethernet: 
10/100Mbit
Lan ports: 
0
LAN ethernet switch: 
Yes
WiFi: 
Yes
WiFi AP mode: 
Yes
Blue Tooth 4.0 LE: 
Yes
Serial port (RS-232): 
No
DHCP: 
Yes
SNTP: 
Yes
SMTP (TLS): 
Yes
SSL: 
Yes
IPv6: 
Yes
VLAN: 
Yes
Syslog: 
Yes
SMS Alerts: 
Yes
Email alerts: 
Yes
Mobile App: 
No
Scheduler (Chytrý kalendář): 
Yes
IP Watchdog Hearbeat): 
No
Warranty 2: 
6 Months
Protection 2: 
IP30
Rack montage: 
None
Product dimensions: 
340 x 58 x 90 mm
Product weight: 
1,18 Kg
Shipping package: 
420 x 65 x 130 / 1350 g
HTTP: 
Yes
HTTPs: 
Yes
SNMP v1: 
Yes
SNMP v3: 
Yes
User certificates: 
Yes
XML: 
Yes
Modbus/TCP: 
Yes
Telnet/Kshell: 
Yes
CGI: 
Yes
MS Azure (MQTT): 
Yes
SIP VoIP: 
Yes
Power Output: 
4x DE (Type F - Schuko)
Power Input: 
230V AC
Power Output sockets: 
1
Power Input: 
Europlug - cable 1m
Power In max current: 
10A
Max one socket current: 
8A
Power fuse: 
External, mechanical
Current meter: 
No
Metered values: 
None
Energy meter: 
No
LUA: 
Yes
XML interface accessible in LUA: 
Yes
SNMP interface accessible in LUA: 
Yes
Web buttons accessible in LUA: 
Yes
CGI interface accessible in LUA: 
Yes
PING interface accessible in LUA: 
Yes
RS-232 accessible in LUA: 
No
Symbol: 
Show download for mobile: 
1

Ask for a price or technical parameters

For device testing use name/password demo/demo